SSI Absolute Encoder
Input Format: Serial Synchronous Interface (SSI)
Clock/Data Signal Levels: Differential TTL (RS-422/485)
Clock Speed: 100 kHz
# of bits: 8 to 32 (programmable)
Incremental Encoder
Input Format: A/B Quadrature with Index
Signal Levels: 5V, 12-15V, 24V (select in model number)
Signal Input Current: 10 mA nom.
Input Frequency Response: 1.0 MHz Max
# of bits: 8 to 32 (programmable)
Dual Encoder USB Converter
SSI and Quadrature Versions Available
SPECIFICATIONS (Module)
Supply Voltage: 5 V ± 5% (powered by USB port)
Supply Current: 100 mA Max
Input Devices: 2 SSI Absolute or 2 Incremental Encoders
Output Format: USB 2.0
Note: Encoders powered separately by external supply.
O
p
eratin
g
Tem
p
erature: 0
o
to 70
o
C
The Dual Encoder to USB Converter translates
encoder position to industry standard USB 2.0 format
that can be read by a computer. Each module can
handle signals from two encoders. Modules are
available for SSI absolute encoders, as well as
quadrature incremental encoders.
The module can be programmed through the USB
interface for number of bits with absolute encoders. For
incremental encoders, count mode (X1, X2, X4), reset,
preset, and preset/reset on index are programmable
through the USB input. Incremental encoder counter
register length is programmable, up to 32 bits. The
Encoder to USB Converter is ideal for system setup and
debugging, data acquisition and PC based control
applications. 3-meter USB cable included.
*Optional programmable data sample function allows
module to automatically capture readings on an accurate
time clock. See -S in Ordering Options below.
SPECIFICATIONS (Encoder)
ENCODER USB CONVERTER ORDERING OPTIONS For assistance, call 800-350-2727(ASAP)
Use this diagram to construct your model number (example: EM-DR1-SS-S3-TB-USB).
DR1
Package Style:
DR1 = 114.5 mm x 99 mm x 22.5 mm
EM
Type:
EM = Electronic Module,
DIN Rail Mount
Output Interface Format:
USB = USB 2.0
Function:
SS = Serial-Serial (SSI to
USB)
QS = Quadrature-Serial
(Quadrature to USB)
Output Voltage from Encoder:
S3 = SSI (used with SS function only)
5 = 5 VDC
15 = 12-15 VDC
24 = 24 VDC
Output Termination:
TB = Standard Terminal Block
Special Features:
S = Special Features
specified on purchase
order (consult factory)
*For data sample, add
-S to model and specify
this function on purchase
order.
TB USB
MECHANICAL SPECIFICATIONS
Package dimensions are 114.4 mm high by 99 mm wide by 22.5
mm thick. The package mounts to a DIN rail type EN 50 022
(35mm X 7.5mm). A length of DIN rail is supplied with each
module. The module simply snaps directly to the DIN rail and is
ready to use.
22.5 mm
(0.89 inches)
114.5 mm
(4.51 inches)
99 mm
4.45 inches
Incremental
Front View
SSI
Front View
USB
Connector
USB
Connector
.
.
.
.
.
.
.
.
.
.
.
.
Tel:805-968-0782 / 800-350-2727 | Fax: 805-968-3154 / 800-960-2726
7230 Hollister Ave., Goleta, CA 93117 | www.beisensors.com
Specification No. 02109-001 Rev. 06/11
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - Dual Encoder USB Converter

SSI Absolute Encoder Input Format: Serial Synchronous Interface (SSI) Clock/Data Signal Levels: Differential TTL (RS-422/485) Clock Speed: 100 kHz

Page 2 - Single Ended Line Driver

Tel:805-968-0782 / 800-350-2727 | Fax: 805-968-3154 / 800-960-2726 7230 Hollister Ave., Goleta, CA 93117 | www.beisensors.com Specification No. 02

Page 3 - ENCODER

Tel:805-968-0782 / 800-350-2727 | Fax: 805-968-3154 / 800-960-2726 7230 Hollister Ave., Goleta, CA 93117 | www.beisensors.com Specification No. 02

Page 4 - (see page 3)

Tel:805-968-0782 / 800-350-2727 | Fax: 805-968-3154 / 800-960-2726 7230 Hollister Ave., Goleta, CA 93117 | www.beisensors.com Specification No. 02

Page 5

Tel:805-968-0782 / 800-350-2727 | Fax: 805-968-3154 / 800-960-2726 7230 Hollister Ave., Goleta, CA 93117 | www.beisensors.com Specification No. 02

Page 6 - GENERAL COMMAND SET

L - Set SSI Data Read Length This command sets the expected data length for each attached SSI encoder. Valid data length values are from 08 to 32